Tinted Float Glass

Description
  • Şişecam Tinted Float Glass  is the trademark of body tinted float glass range of Şişecam Flat Glass.
  • Manufactured by adding coloring agents to the raw batch before melting process.
  • Green, gray, bronze, blue, turquoise, dark smoky and azure blue colors are available.
  • Basic product for solar control.
  • Base glass for coated glass and mirror production.
  • Edgeworking can be applied.
  • Can be used as single glazing.
  • Can be incorporated into insulating glass unit with clear float or Heat Control (Low-E coated) Glass.
  • By applying secondary processes to Şişecam Tinted Float Glass; laminated glass, toughened glass,
    heat strengthened glass, enamalled glass, bent glass, coated glass, acid etched glass, sandblasted glass and mirror can be produced.
  • Solar control glasses are subjected to thermal breakage risks. In order to avoid thermal breakage risks, toughening or heat strengthening is recommended.
  • Şişecam Tinted Float Glass is intended;- primarily for non-residential buildings with curtain walls, which require solar
    control for windows, spandrels, facade claddings, overhead glazing and   balustrades,- additionally for interior applications such as tabletops, shelves, doors, shower   cabins and partitions.
Thickness and Sizes
Product Nominal
Thickness
Standard Sizes (Inch) Tolerance on Thickness (Inch)
Şişecam Tinted Float Glass Green 3mm (1/8") 84x126
88x126
± 0.008
4mm (5/32") 84x126
88x126
± 0.008
5mm (3/16") 84x126
88x126
± 0.008
6mm (1/4") 84x126
88x126
± 0.008
8mm (5/16") 84x126
88x126
± 0.008
10mm (3/8") 84x126
88x126
± 0.008
Şişecam Tinted Float Glass Gray 4mm (5/32") 84x126
88x126
± 0.008
5mm (3/16") 84x126
88x126
± 0.008
6mm (1/4") 84x126
88x126
± 0.008
8mm (5/16") 84x126
88x126
± 0.012
10mm (3/8") 84x126
88x126
± 0.012
Şişecam Tinted Float Glass Bronze 4mm (5/32") 84x126
88x126
± 0.008
6mm (1/4") 84x126
88x126
± 0.008
Şişecam Tinted Float Glass Blue 4mm (5/32") 84x126
88x126
± 0.008
6mm (1/4") 84x126
88x126
± 0.008
8mm (5/16") 84x126
88x126
± 0.012
* The tolerances on nominal sizes are  ± 3/16"* In addition to above data, other thickness and sizes requests, please contact us.
Applications

millireasurans_2Şişecam Tinted Float Glass is intended

  • primarily for non-residential buildings with curtain walls, which require solar control for windows, spandrels, facade claddings, overhead glazing and balustrades.
  • additionally for  interior applications such as tabletops, shelves, doors, shower cabins and partitions.
Processing

Storage

  • Glass packs or crates should be stored at an angle of 5o from the vertical. If bowing of the crates is observed, they should not be stored further and the row should be unpacked immediately.
  • Glass packs or crates should not be stored outside. They should be stored in a closed environment where appropriate temperature and humidity conditions are provided. Recommended values for storage:  temperature between 9-25oC, humidity <70% .  During the storage of the packs and the crates, contact with rain, snow or any kind of water should be avoided. High risk of corrosion should be considered when the glass panes get wet during storage. Therefore, if the glass panes get wet because of condensation or any other reason, they should be cleaned immediately before drying.
  • The loading or unloading of the packs from the stillages should be well balanced.
  • For the storage of the Jumbo packs, wooden wedges with rubber are recommended.
  • For the storage of the machine or split sizes, wooden or metal (with rubber) wedges are recommended.
  • Stillage and the wedges should be supported with rubber pieces in order to tolerate the level differences that are originating from the ground.
  • Wooden wedges should be made out of hornbeam or beech that are dried in an oven.
  • Glass packs, in which there are broken or cracked panes, must not be stored.

 

Washing

  • Hardness of the water to be used for washing the glass panes should be maximum 5o Fr and pH should be between 6-8. The electrical conductivity of the washing water is recommended as 1 µS/cm for the glasses to be coated off-line and less than 30 µS/cm for insulating glass units. Brushes of the washing machine should be soft in order to avoid scratches on the glass. The water on the glass should be removed with air knife before drying.

 

Carrying and Handling (in the plant)

 

  • Glass packs or crates should be carried at an angle of 5o from the vertical. (Never horizontal)
  • Outdoor transportations should be made with closed vehicles that are protected from dust and water.
  • There should not be any broken or cracked panes inside the glass packs. Broken or cracked panes have the risk to scratch the glasses by side, and may cause injury.
  • Glass packs should be stepped on rubber or pad floor. Direct contact with metal or wood should be avoided.
  • An appropriate interleaving material such as powder or paper should be used between the glass panes. Inappropriate material can cause scratches, cracks and corrosion. In case of paper used as interleaving material, the pH should be between 5,5-7 and it should not leave any ash when it is burned.
  • All interleaving material should be clean and dry.
  • Loading and carrying equipment should undamaged.
  • Glass packs or crates should be fastened to the vehicle during transportation.
  • Loading or unloading of the glass packs or crates to the vehicle should be carried out with appropriate equipment.  Inappropriate equipment can cause accidents and breakages of glass. Removing the packages of glass should be made with care.

 

Cutting

 

  • Cutting wheel, cutting oil and cutting pressure should be appropriate.
  • The glass should be snapped off immediately after cutting process is completed.
  • The surfaces of the cutting tables should be clean and smooth.
  • The glass that will be cut should have the same temperature all around. Glass that is exposed to sunshine may not be cut properly because of the temporary stresses.
  • If glasses are heat-treated above 480oC, cutting and breaking problems can occur due to the secondary processes.
Performance Tables
Quality

Şişecam Tinted Float Glass range is manufactured in accordance with EN 572-2 Glass in Building- Basic Soda Lime Silicate Glass Products - Part 2: Float glass.

CE

ce_logo